Serving the Water and Wastewater Industry since 1967
N-CON Systems Company, Inc.
180 North Street
Crawford, GA 30630
800-932-6266

 

NADP approved for NTN Sites

Closed cover sealing sample collection container

Interior with Glass sample train

  • Compact to minimize splash area
  • Prompt opening and closing of sample container
  • Does not “hunt” under marginal precipitation conditions
  • Reliable, heavy duty cover drive motor
  • Easy mounting
  • Operates on 110VAC/220VAC
  • Plug & Play replacement parts
  • Responsive to light snow, drizzle or heavy fog
  • Variety of sample trains available

Collection of uncontaminated samples is essential to the validity of precipitation chemistry. 

The MDN’s compact design minimizes splash from exterior surfaces and  self induced  wind turbulence.  A compression seal on the underside of the cover prevents leakage of dry deposition into the container and retards sample evaporation.  When the sampler cover is opened, the underside is protected from ground splash by a shield that covers, but does not contact the seal.

An infrared, optical precipitation sensor detects the onset of precipitation and uncovers the sample container within sensing 5 drops.  Within two minutes after precipitation stops, the cover returns to seal the collector funnel and minimize exposure to dry deposition.  Sensitivity may be changed in the field. Sensor also detects drizzle, heavy fog or light snow, which may carry significant amounts of deposition

Thermostatically controlled heating and ventilating fan in the housing optimizes sample preservation. Heating of collection funnel minimizes snow build-up. A thermoelectric refrigeration system is available for extremely high ambient installations.

Heavy duty cover drive is rated for 20 years of typical service.  All parts are easy to replace without special tools.

The MDN is easily mounted on a 2” NPS pipe by a socket secured with 2 set screws,

The control system provides an auxiliary contact that closes during precipitation..  This contact can operate a user furnished data logger or event recorder pen in a Belfort Universal Rain gage.  System will also interface with a variety of electronic  weighing rain gages in NADP installations

 

How it Works:

The infrared, optical precipitation sensor detects the onset of precipitation and uncovers the sample container within five (5) drops.  Within two minutes, after precipitation stops, cover returns to sample container to minimize exposure to dry deposition.  Sensor also detects drizzle, heavy fog or light snow, which may carry significant amounts of deposition.

Collection of uncontaminated wet deposition samples is essential to precipitation chemistry validity.  Compact design minimizes splash from exterior surfaces.  In areas with high wind, the sampler may be fitted with an optional Alter Screen.  The compression seal on the underside of the cover prevents leakage of dry deposition in to the container and retards sample evaporation.  When the cover System is opened the underside is protected from ground splash by a shield that covers, but does not contact the seal.

Reliability is essential to the collection of valid samples. The ADS/NTN runs interchangeably on either line power (110VAC or 220VAC) or (12VDC) with an optional external power converter. Cover drive is rated for 20 years of typical service.  All parts are easy to replace without special tools.

The ADS/NTN is mounted on a 2” NPS pipe by a socket secured with 2 set screws, so that it may be easily rotated.

The sampler also provides a 4 conductor cable to connect to an unpowered auxiliary contact that closes during precipitation events.  This contact can operate a user furnished data logger and/or event recorder pen in a Belfort Universal Raingage.  System will also interface with a variety of electronic, weighing rain gages.

A normally open contact is also provided for monitoring power continuity.

Technical Specifications:

DIMENSIONS:
17” (43cm) Wide (less sensor)
19” (46 cm) Deep (less splash shield)
27” (68 cm) High

WEIGHT:
Net: 51 Pounds ( 24 Kg)
Shipping: 68 Pounds ( 32 Kg.)

MATERIALS OF CONSTRUCTION:
Housing:
Aluminum Alloy, seam welded
White polyester powder coat
Sample collector cover:
Aluminum alloy, seam welded
White polyester powder coat

PRECIPITATION SENSOR:
Type: Infra-red transmitter and receiver
Opening: Within 5 drops of onset of precipitation
Closing: Within 2 minutes of end of precipitation
(May be field adjusted to suit site conditions)

POWER REQUIREMENTS:
115VAC or 220VAC (must be specified)
Max: with all heaters 10Amps @ 115 VAC
5Amps @ 220 VAC
Internally fused with lightning protector

GFI (ground fault interrupter) MUST BE USED.

 

 

OUTPUT FOR DATA LOGGER or EVENT RECORDER:

1 Unpowered, normally open contact is closed for the duration of the sampling event.

1 Unpowered, normally open contact is closed to indicate system power is on.

MOUNTING:
Direct mounting on 2” NPS pipe
(2.375 Dia. 68mm Dia.)
With mounting collar and 2 set screws

NADP MDN SAMPLE TRAIN:
NADP MDN sites are furnished with glass sample trains as part of MDN network contract.

OTHER SAMPLE TRAINS:
(19-128)
Glass funnel, glass anti-evaporation capillary, glass sample bottle (2 liter)

(19-130)
Polyethylene funnel with connector and 1.5 liter HDPE sample container

OPTIONAL EXTRAS:
01-090 Support for dry deposition collector
17-125 Thermoelectric refrigeration system to replace
Exhaust fan assembly.
MUST be ordered with sampler. Can not be retrofit
17-505 Thermometer, C° Max, Min & Current
17-510 Thermometer, F° Max, Min & Current
19-135 Dry deposition collector